Settlement System (VW)

Settlement System (VW)



Order

Description

The Model 4660 Settlement System uses a Pressure Transducer attached to a settlement plate located in the settling ground. The sensor is connected, via two fluid filled tubes extending laterally, to a reservoir located on firm ground away from the area of anticipated movement. Fluid pressure within the tubes is sensed by the transducer which provides a measure of the elevation difference between the sensor and the reservoir. The tubes are flushable and the closed loop vented transducer/reservoir system is not influenced by barometric pressure.


Spesification

Standard Ranges¹ 7, 17 m
Resolution
0.025% F.S.
Sensor Accuracy²
±0.1% F.S.
Temperature Range¹ −20°C to +80°C
Length × Diameter 152 × 51 mm (reservoir), 168?×?25 mm (sensor)
Length × Width × Height                              305?×?305?×?6 mm (plate), 305?×?127?×?45 mm (cover)