High Accuracy Column Load Cell | 0.1% | CCDHA

Description

Applied Measurements CCDHA high accuracy column load cell is designed for use in applications where precise compression measurement of mid to high loads and forces is required.

The majority of high accuracy CCD canister load cells that we manufacture are used as reference standards for the calibration or verification of other force transducers and testing machines such as concrete cube crushers and compression testers.

Applied Measurements CCDHA high accuracy column load cell can be supplied with a BS EN ISO 376 calibration certificate issued by a UKAS laboratory or the National Physical Laboratory (NPL) if required.

Feature

  • Capacities: 0-2te up to 0-1500te
  • Output: 2mV/V (1.5mV/V on 500te+)
  • Accuracy: <±0.10%
  • IP67 & IP68 Submersible Options
  • Domed-Top Versions Available
  • Superior Accuracy Guaranteed – Ideal to use as reference cells.
  • Submersible Versions Available – Perfect for marine and off-shore applications.
  • Let us do the work for you – The CCDHA can be supplied as a complete system.

Technical Specifications

Rated Capacity (RC) tonnes 0-2, 0-5, 0-10, 0-25, 0-50, 0-100, 0-200, 0-300, 0-500, 0-1000, 0-1500
Operating Modes Compression Only
Sensitivity (RO) mV/V 1.5 – 2.0 nominal
Zero Balance/Offset ±%/Rated Output 2
Non-Linearity ±%/Rated Output <0.10
Hysteresis ±%/Rated Output <0.10
Repeatability ±%/Rated Output <0.04
Total Error ±%/Rated Output <0.10
Zero Return ±%/Applied Load <0.040
Temperature Effect on Zero ±%/Rated Output / ˚C <0.005
Temperature Effect on Output ±%/Applied Load/ ˚C 0.005
Bridge Resistance Ohms (nominal) 700 (50te and below, plus 1500t), 1400 (100te – 1000te)
Insulation Resistance Megahms @ 500Vdc >500
Excitation Voltage Volts AC or DC 10 recommended (2-15 acceptable)
Operating Temperature Range ˚C -20 to +70
Compensated Temperature Range ˚C +10 to +50
Storage Temperature Range ˚C -20 to +70
Safe Overload % of Rated Capacity 150
Ultimate Overload % of Rated Capacity 250
Deflection @ Rated Capacity See dimensions table
IP Rating (Environmental Protection) IP65 (IP68 available)
Weight (exc cable) See dimension table
Fatigue Life 108 cycles typical (109 cycles on fatigue-rated version)
Cable length metres 4
Cable type 4-core screened, PUR sheath, Ø5 nominal
Construction Stainless Steel
Electrical Connection Cable gland (25te and below)
6-pin mil-spec connector inc. mating cable assembly (50te and above)
Resolution 1 part in 250,000 (with appropriate instrumentation)

Product Dimension

MODEL Capacity (te) H ØA ØK Deflection @ Rated Capacity (nominal) Weight (kg)
CCDHA 0-2 52 28 19 0.1 0.3
CCDHA 0-5 52 28 19 0.1 0.3
CCDHA 0-10 100 45 36 0.2 1.3
CCDHA 0-25 100 45 36 0.2 1.3
CCDHA 0-50 185 70 58 0.35 6.5
CCDHA 0-100 185 100 88 0.35 12
CCDHA 0-200 300 127 113 0.51 30
CCDHA 0-300 325 145 143 0.55 43
CCDHA 0-500 420 180 166 0.72 84
CCDHA 0-1000 590 276 220 0.82 275
CCDHA 0-1500 600 285 238.5 0.99 360

Reviews

There are no reviews yet.

Be the first to review “High Accuracy Column Load Cell | 0.1% | CCDHA”

Your email address will not be published. Required fields are marked *