RK500-03 EC / Salinity Sensor

Description

The probe of EC sensor is made of graphite electrode that has the characteristics of stable performance,high sensitivity, wide application scope. EC sensor is of simple structure, with stable performance, easy for operation, used in the field monitoring of water & salt dynamics in soil.Therefore,it is an ideal observation instrument in the study of generation,evolution,and improvement utilization of saline soil.Also,it can be used in the anti-corrosion monitoring of underground oil,gas pipelines and other pipelines.The sensor an also be directly submerged in liquid,to measure its electrical conductivity.

Soil salinity sensor integrates graphite electrode and precision platinum resistance, to measure the soil salt through temperature compensation algorithm. After submerged into the soil, it can directly test salt content in the soil.

Benefits

  • Fast response.
  • Excellent stability.
  • Widely used.
  • High precision.
  • High sensitivity.
  • Simple operation.

Specifications

Item Technical Specification
EC Salinity
Range 0-20mS/cm 0-0.15mol/L
Supply 5VDC, 12-24VDC
Accuracy ±2%
Response time <1s
Output Signal 4-20mA,0-2V,0-5V,RS485
Electrode Graphite
Housing material ABS
Operating Temperature -30℃-+70℃
Ingress Protection IP68
Storage 10-60℃@20%-90%RH

Product Dimensions

product-RK500-03 EC Salinity Sensor-Rika Sensors-img-6

Installation & Usage

1. In Soil Section installation In the area of need to measure dig a soil profile, determine the position of the sensor and depth in the section, the section on level to dig deep for 10-20 cm round hole, insert the sensor level until the bottom of the hole, then filled out of the clay compaction, to ensure that the sensor electrode surface closely contact with soil.Sensors buried, the soil pit backfill compaction sequence according to the original soil layer. Ground stiletto installation In the measurement area, down from the ground to play a hole to the desired depth, sensor inserted to the bottom of the hole, closely contact with the soil, will then stratified backfill compaction. Measure the soil solution Take a 1 mm sieve separation of 20.00g dried soil, put in 250 ml bottle drying triangle, add distilled water, 100 ml (water:soil = 5:1), oscillation for 5 minutes, the filtered in dry triangle in the bottle.Take the filtered solution 30 ml, placed in small 50 ml beaker, the sensor electrode in the leaching liquid to be tested.
  2. In liquid 2.1 Submerged in liquid directly 2.2 Sumbersible mounting bracket optional
product-Rika Sensors-img-6

Product Detail

Reviews

There are no reviews yet.

Be the first to review “RK500-03 EC / Salinity Sensor”

Your email address will not be published. Required fields are marked *