Flush Diaphragm Pressure Transducer | Flush Pressure Sensor | P600FD

Compact, Rugged and Ideal for Highly Viscous Media

Description

The P600FD flush diaphragm pressure transducer is designed for use in food, process and industrial applications.  It is ideal to use where the media is either viscous, contains particulates or solids, or is otherwise liable to block the port of a conventional pressure transducer with a recessed diaphragm or pressure port.

The P600FD flush diaphragm pressure sensor is also particularly suitable for applications where cavity-free installation or low volumetric displacement is required.

The wetted parts of the flush pressure sensor are manufactured from 316 Stainless Steel and Nitrile, ensuring excellent long-term performance.

The process connection is a ½” BSP male as standard, while electrical output is an industry standard 2 wire 4-20mA signal, which exits through a DIN43650 plug & socket rated to IP65, for harsh environments.

If you need a flush diaphragm pressure transducer for a hazardous environment, we can offer an ATEX certified version, please contact us.

Request pricing from our technical sales team.  If you require a flush diaphragm pressure transducer with a variation on this specification please see our full range of flush pressure sensors.

Features

  • Ranges: 0-5bar up to 0-400bar
  • Outputs: 4-20mA
  • Environmental Protection: IP65
  • Accuracy: <±0.3%/FS
  • ½” BSP or 1″ BSP Pressure Port (1″ BSP only below 6bar)
  • Flush Sensing Diaphragm
  • ATEX Version: II 1 GD EEx ia IIC T4
  • Ideal to use in Viscous/Partially Solid Media – Perfect for the Food Industry
  • ATEX Certified Explosive Atmosphere Versions Available
  • Protected from Low-Pressure Water Jets to Suit Most Environments
  • Save Time With In-Field Span and Zero Adjustments – No need to send in your pressure sensor for re-calibration for those minor changes.
  • Stainless Steel Construction Offers Excellent Long-Term Performance

Specifications

Input pressure range
Nominal Pressure Range Bar (gauge) 5 6 10 16 25 40 60 100 160 250 400
Permissible Overpressure Bar x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.5
Output Signal & Supply Voltage Number of Wires Output Supply Voltage
P642FD 2 – wire 4 – 20mA 13 – 36Vdc (unregulated)
P642FDX 2 – wire 4 – 20mA (ATEX) 13 – 28Vdc (unregulated)
P605FD 3 – wire 0 – 5Vdc 13 – 30Vdc (unregulated)
P6010FD 3 – wire 0 – 10Vdc 13 – 30Vdc (unregulated)
Performance
Accuracy (non-linearity, hysteresis, repeatability) % Full Scale Output <±0.30 (BFSL)
Zero Offset and Span Tolerance % Span ±1
Zero Offset and Span Adjustment % Full Scale Output ±5 with easy access trimming potentiometers
Media Temperature ˚C -20 to +85
Ambient Temperature ˚C -20 to +85 (-20 to +70 ATEX version)
Storage Temperature ˚C +5 to +40
Thermal Zero Shift (TZS) % / FS / ˚C <±0.04 typical
Thermal Span Shift (TSS) % / FS / ˚C <±0.04 typical
Reverse Polarity Protection Protected against supply voltage reversal up to 50Vdc
Media Compatibility Any media compatible with 316L Stainless Steel & Nitrile
Weight grams 90 nominal
Insulation Resistance Megohm @ 50 Vdc >100
Electrical Connection Mating socket with screw terminal connections to DIN 43650
Pressure Connection 1/2” BSPP male with integral Nitrile seal and flush 316L diaphragm. 1” BSPP male wih semi-flush diaphragm optional.
Response Time (10% – 90%) ms ≤1
Environmental Protection IP65
Load Driving Capability 4 – 20mA version supply voltage – 10V / 0.02A (i.e. 36V – 10V / 0.02A = 1300Ω
0-5V / 0-10V versions >5kΩ / >10kΩ
Long Term Stability % / Full Scale < 0.2 / 6 months
Operational Life Pressure Cycles > 108 typical
ATEX Approval (4-20mA versions only) Ex II 1 G Ex ia IIC T4 Ga (zone 0)
Ex II 1 D Ex ia IIIC T135°C Da (zone 20)
EX I M 1 Ex ia I Ma (group I M1)

Wiring Details

Pin No. 2 Wire
(4 – 20mA)
3 Wire
(0 – 5Vdc / 0 – 10Vdc)
1 +ve supply common
2 4 – 20mA signal +ve supply
3 not fitted +ve output
to case to case

ORDERING CODES & OPTIONS

P642FDC-10barg-AA-00-000 (example code) P6 42 FD C 10barg A A 00 000
Product Family
P6–FD P6 FD
Electrical Output
42 = 4-20mA (2 wire) 42
42X = 4-20mA ATEX Certified (2 wire) 42x
Electrical Connection / ATEX Certification
Blank = Large DIN Plug & Socket (standard) Blank
C = IP67 Cable (1 metre fitted as standard) C
CX = IP67 cable + ATEX CX
Pressure Range
10barg = 0 to 10bar gauge 10barg
2400psig = 0 to 2400psi gauge 2400psig
Accuracy (Non-Linearity & Hysteresis)
A = <±0.3%/FS (standard) A
B = Improved Accuracy <±0.15%/FS B
Process Connection
A = G1/2” Male A
B = 1” BSP Male B
Cable Length in Metres
00 = None 00
01 = 1 metre 01
Specials Code
000 = No Special Requirements 000

Product Dimensions

P600FD Flush Pressure Sensor Outline Drawing

All dimensions are in mm

Reviews

There are no reviews yet.

Be the first to review “Flush Diaphragm Pressure Transducer | Flush Pressure Sensor | P600FD”

Your email address will not be published. Required fields are marked *