High Range Pressure Transmitter | 1000bar to 5000bar | P600FA

Titanium Construction with a High Pressure F-250-C Connection

Description

The P600FA high range pressure transmitter is designed for the measurement of pressure across a wide range of general purpose and industrial applications including hydraulics, medical, research and development and a range of steel manufacturing and preparation processes.

The P600FA high range pressure transmitter offers superb media compatibility as standard with its all-Titanium Alloy pressure port and sensing element.  The process connection is a high-pressure F-250-C Autoclave type.

The P600FA high range pressure transmitter offers a 2-wire 4-20mA electrical output as standard while 0-100mV, 0-5Vdc and 0-10Vdc are optional.

Need a higher range? See our DMP304 ultra-high range pressure transducer.

Features

  • Ranges: 0-1000bar up to 0-5000bar
  • Outputs: 4-20mA, 0-5Vdc, 0-10Vdc, 0-100mV
  • Environmental Protection: IP65
  • Accuracy: <±0.25%/FS
  • High Pressure F-250-C Autoclave Fitting
  • Field-Adjustable Span & Zero (±10%)
  • Save Time With In-Field Span and Zero Adjustments – No need to send in your pressure sensor for re-calibration for those minor changes.
  • Titanium Construction Offers Excellent Long-Term Performance
  • Superb Media Compatibility Thanks to its Titanium Alloy Pressure Port
  • ATEX Certified Explosive Atmosphere Versions Available
  • Protected from Low Pressure Water Jets to Suit Most Environments

Specifications

Input Pressure Range
Nominal Pressure Range Bar (gauge) 1000 1500 2000 2500 3000 4000 5000
Permissible Overpressure x nominal x 1.5 x 1.5 x 1.5 x 1.5 x 1.5 x 1.25 x 1.2
Burst Pressure Bar 4000 4000 4000 6000 6000 6000 6000
Output signal & supply voltage Number of Wires Output Supply Voltage Supply Current
P610FA 4 – wire 10 mV/V 5 to 15 Vdc (regulated) 0.6mA/V
P605FA 3 - wire 0 – 5 Vdc 13 to 30 Vdc (unregulated) 13mA
P6010FA 3 - wire 0 – 10 Vdc 13 to 30 Vdc (unregulated) 13mA
P642FA 2 - wire 4 – 20 mA 10 to 36 Vdc (unregulated) N/A
Performance
Accuracy (non-linearity, hysteresis, repeatability) % Full Scale Output <±0.25 (BFSL)
Zero Offset and Span Tolerance % / Span ±0.5% (at room temperature)
Zero Offset and Span Adjustment % / Full Scale Output ±5 adjustment with easy access trimming potentiometers on amplified versions only
Media Temperature ˚C -50 to +125
Ambient Temperature ˚C -40 to +85 (-20 to +70 ATEX Version)
Storage Temperature ˚C +5 to +40
Thermal Zero Shift (TZS) % / FS / ˚C <±0.02
Thermal Span Shift (TSS) % / FS / ˚C <±0.02
Reverse Polarity Protection Protected against supply voltage reversal up to 50Vdc (amplified version only)
Media Compatibility Any media compatible with BT9 Titanium Alloy
Weight grams 125 nominal
Insulation Resistance Megohm @ 50 Vdc >100
Input Resistance and Output Resistance 1500 ±30% (P610FA only)
Electrical Connection Mating socket with screw terminal connections to DIN 43650
Pressure Connection F250-C Autoclave fitting. Thread Type 9/16-18UNF-2B (female)
Response Time (10% - 90%) ms ≤1
Environmental Protection IP65
Load Driving Capability 4 - 20mA version Supply voltage - 10V / 0.02A (i.e. 36V - 10V / 0.02A = 1300Ω
0 - 5V / 0 - 10V versions >5kΩ / >10kΩ
Long Term Stability % / Full Scale < 0.2 / 6 months
Operational Life Pressure Cycles > 108 typical
ATEX Approval (4-20mA versions only) Ex II 1 G Ex ia IIC T4 Ga (zone 0)
Ex II 1 D Ex ia IIIC T135°C Da (zone 20)
EX I M 1 Ex ia I Ma (group I M1)

Wiring Details

Pin No. 2 Wire (4 - 20mA) 3 Wire (0 - 5Vdc / 0 - 10Vdc) 4 Wire (10mV/V)
1 +ve supply common -ve supply
2 4 - 20mA signal +ve supply +ve supply
3 not fitted +ve output +ve output
to case to case -ve output

ORDERING CODES & OPTIONS

P642FAC-1000barg-AA-00-000 (example code) P6 42 FA C - 1000barg - A A - 00 - 000
Product Family
P6--FA P6 FA
Electrical Output
10 = 10mV/V (4 wire) 10
42 = 4-20mA (2 wire) 42
45 = 0.5-4.5Vdc (5V excitation) 45
05 = 0-5Vdc (3 wire) 05
010 = 0-10Vdc (3 wire) 010
Electrical Connection / ATEX Certification
Blank = Large DIN Plug & Socket (standard) Blank
C = IP67 Cable (1 metre fitted as standard) C
X = ATEX Certified X
CX = IP67 cable + ATEX CX
Pressure Range
1000barg = 0 to 1000bar gauge - 1000barg
15,000psig = 0 to 15,000psi gauge - 15,000psig
Accuracy (Non-Linearity & Hysteresis)
A = <±0.25%/FS (standard) - A
B = <±0.15%/FS (FA, FAX & FD versions only) - B
Process Connection
B = F-250C Autoclave (9/16” UNF Female) B
D = M16 x 1.5 Female Cone Seal D
Cable Length in Metres
00 = None - 00
01 = 1 metre - 01
Specials Code
000 = No Special Requirements - 000

Reviews

There are no reviews yet.

Be the first to review “High Range Pressure Transmitter | 1000bar to 5000bar | P600FA”

Your email address will not be published. Required fields are marked *