Description
Applied Measurements AML/IE series of industrial LVDT displacement transducers are available with measuring ranges from ±0.5mm (0-1mm) up to ±500mm (0-1000mm).
Constructed from stainless steel, the AML/IE LVDTs are sealed to IP65 as standard with the option of IP68 (submersible), making them ideally suited for a multitude of harsh and demanding applications where environmental conditions are humid, wet, dusty or dirty.
The basic AML/IE industrial LVDT displacement transducers have an AC mV/V output as standard, with a range of DC voltage signal output options also offered including 0-5Vdc, 0-10Vdc and ±2.5Vdc, as well as a 3-wire 4-20mA current output.
Applied Measurements AML/IE industrial LVDT offers a choice of mechanical configurations including captive guided core & extension rod, which is standard, plus spring-loaded core & extension rod with ball-end or guided core & extension with spherical rod-end bearings.
Please see our full range of LVDT displacement transducers and position sensors. We can also offer a comprehensive variety of supporting instrumentation. Contact Applied Measurements expert and friendly technical team to discuss your requirements.
Specifications
CHARACTERISTICS |
AML/IE |
AML/IEJ |
AML/IEU |
AML/IEU -10 |
AML/IEI |
AML/IED |
UNITS |
Stroke Measurement Range: |
±0.5, ±2.5, ±5, ±10, ±12.5, ±15, ±25, ±50, ±75, ±100, ±125, ±150, ±175, ±200, ±250
±300, ±400, ±500, ±550 (maximum stroke is ±125 for Sprung Loaded Core & Extension) |
millimetres |
Signal Output: |
See Table Below |
0-5volt |
0-10volt |
4-20mA |
±2.5volt |
|
No. of Wires |
6 |
4 |
3 |
3 |
3 |
4 |
|
Supply Voltage (unregulated): |
2 to 5Vrms @ 1 to 5kHz |
10-24Vdc |
14-24Vdc |
14-24Vdc |
12Vdc regulated |
|
Supply Current: |
- |
35mA @ 15V |
35mA @ 15V |
35mA typ. |
35mA @ 12V |
|
Max. Loop Resistance: |
- |
- |
- |
300 @ 30V |
- |
ohms |
Max. Output Sink Current: |
- |
0.5 |
1 |
- |
0.1 |
milliamps |
Non-Linearity: |
<0.50 |
±% Stroke Range |
Repeatability: |
<0.10 |
±% Stroke Range |
Output Bandwidth (flat): |
100 |
Hz |
Output Ripple: |
- |
30mV max. |
30mV max. |
0.1% @
20mA |
30mV max. |
|
Operating Temperature Range: |
AML/IE & IEJ: -30 to +85 Standard / -30 to +150 and +200 Optional
-20 to +85 on DC/DC models / 0 to +70 for in-line conditioner (where fitted) |
°C |
Zero Temperature Coefficient: |
<0.020 |
<0.010 |
±%Stroke Range/°C |
Span Temperature Coefficient: |
<0.020 |
<0.030 |
±%Stroke Range/°C |
Vibration Resistance: |
20g up to 2kHz |
|
Shock Resistance: |
1000g for 10milliseconds |
|
Construction Materials: |
Body & Extension Rod: 303 St/Steel, Core: 416 St/Steel, Cable Gland: Nickel-Plated Brass,
Spring: 316 St/Steel, Rod-End Bearings: Mild Steel (St/Steel on IP68 version) |
|
Connecting Cable: |
2 metre screened PVC cable* (*IP68 = PUR / Hi-Temp = PTFE). |
|
Environmental Sealing: |
IP65 (IP68 optional) |
|
Note: On DC output version (0Vdc / 4mA) is given with the core in the extended / outwards position. This can be reversed if required, please request
Option Y on your order. |
Product Dimensions
-
AML-IE Industrial LVDT Displacement Transducer AC Version Plain Outline
-
AML-IE Industrial LVDT Displacement Transducer AC Version with M6 Rod End Bearings (R+M6) Outline
-
AML-IE Industrial LVDT Displacement Transducer AC Version with M8 Rod End Bearings (R+M8) Outline
-
AML-IE Armoured Hose
Plain Core + Extension AML-IE Industrial AC Version Options: A = axial cable exit; R = radial cable exit; J = 4-wire device; G = extension rod wiper; W = waterproof IP68; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; Z = armoured hose.
Option R M6 AML-IE Industrial AC Version with M6 Rod End Bearings Options: R = radial cable exit ONLY; J = 4-wire device; G = extension rod wiper; W = waterproof IP68; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; Z = armoured hose.
Axial cable exit is NOT available with rod ends unless rod end is on the extension ONLY.
Option R M8 AML-IE Industrial AC Version with M8 Rod End Bearings Options: R = radial cable exit ONLY; J = 4-wire device; G = extension rod wiper; W = waterproof IP68; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; Z = armoured hose.
Axial cable exit is NOT available with rod ends unless rod end is on the extension ONLY.
-
AML-IE Industrial LVDT Displacement Transducer AC Version Sprung-Loaded (S) Outline
Option S AML-IE AC Version Sprung Loaded Options: R = radial cable; A = axial cable; J = 4-wire device; G = extension rod wiper; SW = waterproof IP68; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; Z = armoured hose.
-
AML-IE Industrial LVDT Displacement Transducer DC Version Plain Outline
-
AML-IE Industrial LVDT Displacement Transducer DC Version with M6 Rod End Bearings (R+M6) Outline
-
AML-IE Industrial LVDT Displacement Transducer DC Version with M8 Rod End Bearings (R+M8) Outline
-
AML-IE Industrial LVDT Displacement Transducer DC Version Sprung-Loaded (S) Outline
Plain Core AML-IE Industrial DC Version Options: A = axial cable exit; R = radial cable exit; G = extension rod wiper; W = waterproof IP68 with PU cable; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (e.g. 4mA fully in instead of default 20mA); Z = armoured hose.
H & VH = high temperature options not available
Option R M6 Rod Ends AML-IE Industrial Version with M6 Rod End Bearings Options: R = radial cable exit only; G = extension rod wiper; W = waterproof IP68 with PU cable and stainless steel M6 rod end bearings; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (e.g. 4mA fully in instead of default 20mA); Z = armoured hose.
H & VH = high temperature options not available
Option R M8 Rod Ends AML-IE Industrial DC Version with M8 Rod End Bearings Options: R = radial cable exit only; G = extension rod wiper; W = waterproof IP68 with PU cable and stainless steel M8 rod end bearings; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (e.g. 4mA fully in instead of default 20mA); Z = armoured hose.
H & VH = high temperature options not available
Option S AML-IE Industrial DC VErsion Sprung Loaded Options: R = radial cable exit; A = axial cable exit; G = extension rod wiper; W = waterproof IP68 with PU cable; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (e.g. 4mA fully in instead of default 20mA); Z = armoured hose.
H & VH = high temperature options not available
ORDERING CODES & OPTIONS