Low Differential Pressure Sensor | Dry/Dry | Low DP Transmitter | PR3202

High Stability, Robust, Measurement of Dry, Non-Corrosive Gases

Description

The PR3202 low differential pressure sensor is designed for the measurement of dry, non-corrosive gases across range of general purpose and industrial applications such as HVAC, clean room monitoring and flow measurement applications.

The PR3202 low differential pressure transmitter utilises a highly stable sensing element which allows it’s 4-20mA output to be factory-scaled over measuring ranges as small as 0-0.25mbar (0-25 Pascals). They are also fully temperature compensated for unrivalled stability at very low pressure.

In addition to differential pressure, the PR3202 can also measure gauge and vacuum / suction pressure, it can also operate bi-directionally giving the ability to measure compound differential pressure ranges that range from vacuum to positive pressure.

The PR3202 low range differential pressure sensor’s process connection is made via hose fittings which cater for common mode / line pressures of up to 10bar.

Features

  • Ranges: 0-0.25mbar up to 0-1000mbar
  • Outputs: 4-20mA
  • Line / Common Mode Pressure: 2bar max. (range dependent)
  • Accuracy: <±0.25%/FS
  • Optional ATEX Intrinsically Safe Version (5mbar and above only)
  • Ideal For Dry/Dry Measurements at Very Low Pressures
  • Save Time With User Span and Zero Adjustments – No need to send in your pressure sensor for minor adjustments.
  • ATEX Certified Explosive Atmosphere Versions Available
  • Ideal for HVAC, Clean-Room and Flow Measurement Applications
  • Fully Temperature Compensated for Higher Stability at Low Pressures

Specifications

Input Pressure Range
Nominal Pressure Range mbar 5 10 20 30 50 80 100 250 500 1000
Permissible Overpressure mbar 25 25 200 200 200 200 200 1200 1200 1200
Max Common Mode Pressure / Static Line Pressure mbar 375 375 2000 2000 2000 2000 2000 2000 2000 2000
Output signal & supply voltage Number of Wires Output Supply Voltage Supply Current
PR3202 2 – wire 4 - 20mA 13 - 36Vdc n/a
PR3202X (ATEX version) 2 - wire 4 - 20mA 13 - 28Vdc n/a
PR3202V5 3 - wire 0 - 5Vdc 13 - 30Vdc 13mA
PR3202V10 3 - wire 0 - 10Vdc 13 - 30Vdc 13mA
Performance
Accuracy (non-linearity, hysteresis, repeatability) % Full Scale Output <±0.30 (BFSL)
Zero Offset and Span Tolerance % Span ±1
Zero Offset and Span Adjustment % Full Scale Output ±5 with easy access trimming potentiometer
Media Temperature ˚C -20 to +70
Ambient Temperature ˚C -20 to +70
Storage Temperature ˚C +5 to +40
Thermal Zero Shift (TZS) % / Full Scale / ˚C <±0.04
Thermal Span Shift (TSS) % / Full Scale / ˚C <±0.04
Reverse Polarity Protection Protected against supply voltage reversal up to 50Vdc
Media Compatibility Dry non-corrosive gas only
Weight Grams 280 for standard unit
Insulation Resistance Megohm @ 50 Vdc >100
Electrical Connection: Screw terminals for conductor sizes 0.2-2.0mm2 are located beneath the enclosure lid. Cable entry is through an IP66 cable gland with compression seal for cable sizes 4-8mm. Optional M20 conduit fitting available.
Pressure Connection: 4mm I.D. hose (others on request)
Response Time (10% - 90%) ms ≤10
Environmental Protection: IP65
Load Driving Capability 4 - 20mA version Supply voltage - 10V / 0.02A (i.e. 36V - 10V / 0.02A = 1300Ω
0 - 5V / 0 - 10V versions >5kΩ / >10kΩ
Long Term Stability % / Full Scale < 0.2 / 6 months
Operational Life Pressure Cycles > 108 typical
ATEX Approval (4-20mA versions only) Ex II 1 G Ex ia IIC T4 Ga (zone 0)
Ex II 1 D Ex ia IIIC T135°C Da (zone 20)
EX I M 1 Ex ia I Ma (group I M1)

Wiring Details

Pin No. 2 Wire (4 - 20mA) 3 Wire (0 - 5Vdc / 0 - 10Vdc)
1 +ve supply -ve supply / 0V common
2 4 - 20mA signal +ve supply
3 earth/case output signal

ORDERING CODES & OPTIONS

PR3202X-1000mbar-AA-00-000 (example code) PR3202 X - 1000mbar - A A - 00 - 000
Product Family
PR3202 PR3202
Electrical Output
Blank = 4-20mA (2-wire) Blank
X = 4-20mA ATEX Certified (2-wire) X
V5 = 0-5Vdc (3-wire) V5
V10 = 0-10Vdc (3-wire) V10
Electrical Connection
Blank = Cable Gland (suits 4-8mm diameter cable)
Pressure Range
1000mbar = 0 to 1000mbar differential - 1000mbar
10psi = 0 to 10psi differential - 10psi
M500P500mbar = -500 to +500mbar differential - M500P500mbar
Process Connection
A = Male Hose Barb Fittings (suit 4mm ID hose) - A
B = 1/4” BSP Male Threaded Connection - B
Housing Type
A = Standard A
B = Aluminium B
Cable Length
00 = None - 00
01 = 1 metre - 01
Specials Code
000 = No Special Requirements - 000

Product Dimensions

PR3202 Low Differential Pressure Sensor Outline Drawing

Reviews

There are no reviews yet.

Be the first to review “Low Differential Pressure Sensor | Dry/Dry | Low DP Transmitter | PR3202”

Your email address will not be published. Required fields are marked *